Model NumberCg-50

Mass Accuracy Grade0.2

Max. Flowrate1000kg/Min

Temperature Accuracy±1°c

Zero Stability0.038kg/Min

Nominal Diameter50mm (2 Inch)

Max. Operating Pressure4mpa

Material Of TubeStainless Steel 316l

Operating Temperature-50~200°c

Operating VoltageAc220v/50hz, Dc24/50hz

Ex-proof GradeEx[ib]iibt4gb

Place Of OriginZhejiang, China

Supply Ability & Additional Information

PackagingCarton/wooden case

TransportationOcean

Supply Ability300 Set/Sets per Month We have mass flow meters in stock.

PortPort Ningbo

Payment TypeL/C,T/T,Western Union

Packaging & Delivery
Selling Units:
Set/Sets
Package Type:
Carton/wooden case


Specifications


Specifications of Mass Flow Sensor

Specifications of mass flow sensor

Gas accuracy

±0.5%

Liquid accuracy

±0.2%

Temp. accuracy

±1°C

Loss of pressure

≤0.2MPa

MWP

4MPa

Temp. rating

-50°C~+200°C

Connector

DN50, flange, customizable

Ex-proof grade

Ex[ib]IIBT1~T6 Gb / Ex[ib]IICT1~T6 Gb


Specifications of Mass Flow Transmitter

Specifications of mass flow transmitter

Temp. rating

-20°C~+50°C

RH

95%, not condensed

 Atmospheric Pressure

86~106 kPa

Operating voltage

AC220V/50Hz, DC24/50Hz

Communication port

RS485 Modbus RTU

Ex-proof grade

Exd[ib]IIBT4Gb


Specifications of Mass Flow Meter

Specifications of mass Flow Meter

Model No.

CNG-50

Mass accuracy grade

0.2

Temperature accuracy

±1°C

Zero stability

0.038kg/min

Repeatability

0.25%

Max. flowrate

1000kg/min

Nominal diameter

50mm( 2 inch)

Fluid temperature

-200~200°C

Material of tube

Stainless steel 316L

Packing

1set/carton or wooden case

Warranty

2 years

Package size

970*950*600mm

G.W.

68.3kgs


Introduction


Introduction of mass flow meter

Mass flow meter consist of mass flow sensor and mass flow transmitter. It does not measure the volume per unit time (e.g., cubic meters per second) passing through the device, but measures the mass per unit time (e.g., kilograms per second) flowing through the device. The result of volumetric meter varies with temperature, pressure, composition, etc., but mass flow meter does not have such problem.


Application of mass flow meter

The Sealand Coriolis Flow Meter family measures direct mass flow rates of liquids and gases in virtually all applications without special calibration. Safety, reliability, quality, and our innovative technologies enables us to provide a broad range of industry-specific products and services — and the expertise to put them to work for you.

  • Alternative Energy
  • Oil & Gas
  • Chemical
  • Food & Beverage
  • Industrial Energy
  • Life Sciences
  • Marine
  • Metals and Mining
  • Power
  • Pulp & Paper
  • Refining
  • Water & Wastewater
  • Others

Pictures of mass flow meter

LPG mass flowmeter with high accuracy


Dimension of mass flow meter  

 LPG mass flowmeter with high accuracy


Advantages of mass flow meter


1. High reliability


2. It requires low maintenance, because of no movable parts.


3. High accuracy: Generally, it is from 0.15%-0.3%.


4. It is not affected by the fluid, saving the design & installation cost.


5. It shows many parameter simultaneously, such as mass flow, temperature, density, etc.


Installation of mass flow meter 

It is highly recommended to install as follows, for different fluid.

LPG mass flowmeter with high accuracy


Production Process


Production process of mass flow meter

1. Bend vibrating tubes with bending machine

LPG mass flowmeter with high accuracy

 
2. Smear the solder on the production line
LPG mass flowmeter with high accuracy
 
3. Solder the tubes in the Vacuum brazing furnace
LPG mass flowmeter with high accuracy
 
4. Wire the Mass Flowmeter (at the same production line of step 2)
 
5. Test for the 1st time
LPG mass flowmeter with high accuracy
 
6. Burn-in: Mass Flowmeter will be excercised for 15 days prior to being placed in service.
LPG mass flowmeter with high accuracy
 
7. Test for the 2nd time (at the same production line of step 5)

8. Cover the tubes with housing & polish the surface (at the same production line of step 2)

9. Test for the 3rd time(final test; this test equipment is approved by China government, and is the
    TEST STANDARD of mass flowmeter in China)
LPG mass flowmeter with high accuracy

Bulk order of mass flow meter

LPG mass flowmeter with high accuracy



Certificate of mass flow meter

LPG mass flowmeter with high accuracy

Product Categories : LPG Mass Flow Meter

Email to this supplier
  • *Subject:
  • *To:
    Mr. Will
  • *Email:
  • *Message:
    Your message must be between 20-8000 characters
HomeProductsLPG Mass Flow MeterLPG mass flowmeter with high accuracy
Send Inquiry
*
*

Related Products List

Home

Product

Whatsapp

About Us

Inquiry

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send